Call_Nbr Strategy

 

Different projects have different requirements on calling number, some projects’s RM_Nbr is matched with the calling number, we call it Regular digital numbers , some projects require alphanumeric, or shortcut call, what is more, to make group call and etc. (we call it Irregular numbers requirement)

Thanks to Call_Nbr, all these requirements can be achieved.

Regular digital numbers

In most installation, the RM_ADDR is matched with the calling number, so it is easy to make a call as below:

  • On block Door Station, input RM_Nbr (1~4 digital numbers)

  • On common Door Station, input BD_Nbr & RM_Nbr (5~8 digital numbers)

What you can do more?

  1. set the calling number digits

  2. set the timing and min/max digits of auto call mode

Irregular numbers

Thanks to the Call_Nbr, we can solve the problem of irregular number calls . These settings can be directly operated on the local machine or configured in the resource file in the tool.

We have listed the following requirements and examples

 

Appendix

Regular digital numbers call in building

In the SS (standalone apartment) , use the RM_Nbr as the calling number on block door station.

the default RM_Nbr is 4 digits, zero out before number is supported when calling.

In the NS (Network system) , use the BD_Nbr+RM_Nbr as the calling number on common door station.

the default BD_Nbr+RM_Nbr is 8 digits, zero out before number of BD_Nbr is supported when calling.

In the list calling mode, to make a call, you can sort by RM_Nbr or Name

Building : A-0001

 

Building : A-0002

BD_RM_MS

NAME

LOCAL

GLOBAL

DEVICE_TYPE

 

BD_RM_MS

NAME

LOCAL

GLOBAL

DEVICE_TYPE

0001 0001 (01)

Jim

-

-

IM

 

0002 0001 (01)

Ahi

-

-

IM

0001 0002 (01)

Hebe

-

-

IM

 

0002 0002 (01)

Bill

-

-

IM

0001 0003 (01)

Jeff

-

-

IM

 

0002 0003 (01)

Tim

-

-

IM

0001 0004 (01)

Alan

-

-

IM

 

0002 0004 (01)

Dan

-

-

IM

0001 0005 (01)

Eden

-

-

IM

 

0002 0005 (01)

Ien

-

-

IM

0001 0006 (01)

Polly

-

-

IM

 

0002 0006 (01)

Sea

-

-

IM

0001 0007 (01)

Mina

-

-

IM

 

0002 0007 (01)

Mike

-

-

IM

0001 0008 (01)

Annie

-

-

IM

 

0002 0008 (01)

John

-

-

IM

0001 0000 (01)

A-0001

 

 

DS

 

0002 0000 (01)

A-0002

 

 

DS

0000 0000 (01)

 

 

 

CDS

 

 

 

 

 

 

 

Alphanumeric /shortcut calls in building

In some projects, it is necessary to call monitors with fixed numbers or alphanumeric.

Local_Nbr is used to realize it when make a call on the block door station

Global_Nbr is used to realize it when make a call on the common door station

you also can make the Name to make a call in list.

Building : A-0001

 

Building : A-0002

BD_RM_MS

NAME

LOCAL

GLOBAL

DEVICE_TYPE

 

BD_RM_MS

NAME

LOCAL

GLOBAL

DEVICE_TYPE

0001 0001 (01)

Jim

1-01

A101

IM

 

0002 0001 (01)

Ahi

2-01

B201

IM

0001 0002 (01)

Hebe

1-02

A102

IM

 

0002 0002 (01)

Bill

2-02

B202

IM

0001 0003 (01)

Jeff

1-03

A103

IM

 

0002 0003 (01)

Tim

2-03

B203

IM

0001 0004 (01)

Alan

1-04

A104

IM

 

0002 0004 (01)

Dan

2-04

B204

IM

0001 0005 (01)

Eden

1-05

A105

IM

 

0002 0005 (01)

Ien

2-05

B205

IM

0001 0006 (01)

Polly

1-06

A106

IM

 

0002 0006 (01)

Sea

2-06

B206

IM

0001 0007 (01)

Mina

1-07

A107

IM

 

0002 0007 (01)

Mike

2-07

B207

IM

0001 0008 (01)

Annie

1-08

A108

IM

 

0002 0008 (01)

John

2-08

B208

IM

0001 0000 (01)

A-0001

 

 

DS

 

0002 0000 (01)

A-0002

 

 

DS

0000 0000 (01)

 

 

 

CDS

 

 

 

 

 

 

 

 

 

Group call and Intercom between monitors

In some special project, there is a requirement for group calling, that is, different indoor units can be called together via one time calling and at the same, indoor units still support intercom function.

The IX system provides the possibility for this requirement, assign different addresses to the different indoor units to get the point to point intercom function, and realizing the group call through Local_Nbr or Global_Nbr setting.

 

Building : A-0001

BD_RM_MS

NAME

LOCAL

GLOBAL

DEVICE_TYPE

0001 0001 (01)

Jim

A1

-

IM

0001 0002 (01)

Hebe

A1

-

IM

0001 0003 (01)

Jeff

B2

C3

IM

0001 0004 (01)

Alan

B2

C3

IM

0001 0005 (01)

Eden

C3

C3

IM

0001 0006 (01)

Polly

C3

C3

IM

0001 0007 (01)

Mina

-

-

IM

0001 0008 (01)

Annie

-

-

IM

0001 0000 (01)

A-0001

 

 

DS

 

Separate call to one monitor

In some special project, there is a requirement for separate calling. For example, in some office buildings, where multiple companies share a receptionist, different company names need to be displayed on the door station, but the same monitor is called.

The IX system provides the possibility for this requirement, if use Keypad call, support max.3 different ways to call one monitor, if use List call, no limited on quantity.

Building : A-0001

BD_RM_MS

NAME

LOCAL

GLOBAL

DEVICE_TYPE

0001 0001 (01)

ABR

-

-

IM

0001 0001 (01)

TRY

02

-

IM

0001 0001 (01)

MNN

-

03

IM

0001 0001 (01)

STT

-

-

IM