Installer - Call_Nbr
  • Draft
  • Installer - Call_Nbr

    Menu

    image-20241105-030431.png

    Default installer password “66666666”

    For using door station DH622/DH611 only, the system type is DH-SS.

    For using door station DH850/DH821 only, the system type is DH-APT.

    Settings (DH-SS)

     

    image-20241105-031224.png

    Menu information

    Item

    Value

    Item

    Value

    System type

    Setup the system type for the monitor,

    DH-SS or DH-APT
    the value here will change the menu layout

    Device_Addr

    Monitor address, 2 digits(in DH-SS 01-08)

    MS_Nbr

    Master/slave address setup

    Name

    Monitor name

    Local_Nbr

    Extension call numbers

    Manually setup monitor address in DH-SS

    Tap the “Device_Addr” in the menu and input the 2 digital room numbers.

    Tap the “MS_Nbr” in the menu and input MS_Nbr to set up master and slave settings.

    01: Master

    02~04: Slave

    For DH-SS automatically setup address is supported in DH-SS onsite tool

     

    Settings (DH-APT)

     

    Menu information

    Item

    Value

    Item

    Value

    System type

    Setup the system type for the monitor,

    DH-SS or DH-APT
    the value here will change the menu layout

    RM_Addr

    Monitor address, 2 digits

    MS_Nbr

    Master/slave address setup

    Name

    Monitor name

    Local_Nbr

    Extension call number

    Global_Nbr

    Extension call numbers. Reserved.

    Update Call_Nbr from RES

    After configure RM_Addr, get Call_Nbr information form door station MAT according to configured RM_Addr (if has)

    Restore Call_Nbr default

    Release the address setup, and set to default settings.

    Setup monitor address in DH-APT

    Room address

    Tap the “RM_Nbr” in the menu and input the 2 digital room numbers.

    If the system has configured a MAT via the door station

    After tapping “RM_Nbr” instead, the monitor will display the selectable MAT.

    Tap “Input,” to manually input an address,

    or select one from the MAT.

    Master and Salve settings.

    Tap the “MS_Nbr” in the menu and input the 2 digital room numbers.

    If the system has configured a MAT via the door station

    If MAT has been configured in the system, tap “MS_Nbr” will request to input the room number, and then select a Master/Slave address.

    Related content

    Installer - Onsite Tool (DH-APT)
    Installer - Onsite Tool (DH-APT)
    Read with this
    DH-BC4
    DH-BC4
    Read with this
    Installer - Onsite Tool (DH SS )
    Installer - Onsite Tool (DH SS )
    Read with this
    DH SS System Commissioning Steps
    DH SS System Commissioning Steps
    Read with this
    DH APT System Commissioning
    DH APT System Commissioning
    Read with this
    DH APT Wiring and Capacity
    DH APT Wiring and Capacity
    Read with this