DH APT Wiring and Capacity
Release
DH APT Wiring and Capacity
Typical wiring for apartments
1. with no more than 16 monitors
Distance Limit
Cable Type | A | B |
---|---|---|
2 x 0.75 mm² | 60 M | 90 M |
2 x 1.00 mm² | 75 M | 100 M |
UTP cable (4 + 4 Combine) | 40 M | 40 M |
2. with no more than 32 monitors
Distance Limit
Cable Type | A | B | C |
---|---|---|---|
2 x 0.75 mm² | 60 M | 90 M | 90 M |
2 x 1.00 mm² | 75 M | 100 M | 100 M |
UTP cable | 40 M | 40 M | 40 M |
3. with no more than 48 monitors
Distance Limit
Cable Type | A | B | C | D | Cat5 |
---|---|---|---|---|---|
2 x 0.75 mm² | 60 M | 90 M | 90 M | 90 M | 80 M |
2 x 1.00 mm² | 75 M | 100 M | 100 M | 100 M | 80 M |
UTP cable | 40 M | 40 M | 40 M | 40 M | 80 M |
4. with no more than 64 monitors
Distance Limit
Cable Type | A | B | C/D/E | Cat5 |
---|---|---|---|---|
2 x 0.75 mm² | 60 M | 90 M | 90 M | 80 M |
2 x 1.00 mm² | 75 M | 100 M | 100 M | 80 M |
UTP cable | 40 M | 40 M | 40 M | 80 M |