DH APT Wiring and Capacity
  • Release
  • DH APT Wiring and Capacity

    Typical wiring for apartments

    1. with no more than 16 monitors

    image-20241031-052419.png

    Distance Limit

    Cable Type

    A

    B

    Cable Type

    A

    B

    2 x 0.75 mm²

    60 M

    90 M

    2 x 1.00 mm²

    75 M

    100 M

    UTP cable (4 + 4 Combine)

    40 M

    40 M

     

    2. with no more than 32 monitors

     

    image-20241031-053638.png

    Distance Limit

    Cable Type

    A

    B

    C

    Cable Type

    A

    B

    C

    2 x 0.75 mm²

    60 M

    90 M

    90 M

    2 x 1.00 mm²

    75 M

    100 M

    100 M

    UTP cable

    40 M

    40 M

    40 M

     

    3. with no more than 48 monitors

    Distance Limit

    Cable Type

    A

    B

    C

    D

    Cat5

    Cable Type

    A

    B

    C

    D

    Cat5

    2 x 0.75 mm²

    60 M

    90 M

    90 M

    90 M

    80 M

    2 x 1.00 mm²

    75 M

    100 M

    100 M

    100 M

    80 M

    UTP cable

    40 M

    40 M

    40 M

    40 M

    80 M

     

    4. with no more than 64 monitors

     

    Distance Limit

    Cable Type

    A

    B

    C/D/E

    Cat5

    Cable Type

    A

    B

    C/D/E

    Cat5

    2 x 0.75 mm²

    60 M

    90 M

    90 M

    80 M

    2 x 1.00 mm²

    75 M

    100 M

    100 M

    80 M

    UTP cable

    40 M

    40 M

    40 M

    80 M

     

    Related content

    Wiring 16 monitors (DH-SS/DH-APT)
    Wiring 16 monitors (DH-SS/DH-APT)
    Read with this
    DH SS Wiring and Capacity
    DH SS Wiring and Capacity
    Read with this
    Power and System Capacity
    Power and System Capacity
    Read with this
    DH APT System Commissioning
    DH APT System Commissioning
    Read with this
    Wiring 32 monitors (DH-SW4)
    Wiring 32 monitors (DH-SW4)
    Read with this
    DH SS System Commissioning Steps
    DH SS System Commissioning Steps
    Read with this