Wiring 32 monitors (DH-SW4)
  • Release
  • Wiring 32 monitors (DH-SW4)

    The wiring support for less than 16 monitors.

    Wirings

    Use DH-SW4 to extend the extra 16 monitors

    image-20241129-024800.png

     

    Support wiring the same as Wiring 16 monitors (DH-SS/DH-APT)

    • Daisy Chain

    • Star

    • Free run

    • Structure wiring

    Distance limitation

    General

    image-20241202-030231.png

    A: Power supply to door stations

    B: Power supply to monitors, and to DH-SW4

    C: DH-SW4 to monitors

    Cable Type

    A

    B

    C

    Cable Type

    A

    B

    C

    2 x 0.75 mm²

    60 M

    90 M

    90 M

    2 x 1.00 mm²

    75 M

    100 M

    100 M

    UTP cable

    40 M

    40 M

    40 M

     

    More specific

     

    Wiring 1 and Wiring 2 have the same rules,

    In the case of using cable 2 x 0.75 mm²

    • From the power supply to door stations (A), it is less than 75 meters. ( Wiring 2 usually doesn’t has DS)

    • From the power supply to monitors less than 90 meters.

    And 1 and 2 separately same with Wiring 16 monitors (DH-SS/DH-APT)

     

     