Power and System Capacity
  • Rough draft
  • Power and System Capacity

    The capacity has two limits, power limit and system limit

    General Limit - Power Supply

    One screen working at a time.

    Name

    Max Capacity DS

    Max Capacity IM

    Certification

    2Easy DT*

    Name

    Max Capacity DS

    Max Capacity IM

    Certification

    2Easy DT*

    PC9

    2

    3 (7“)

    image-20250211-080303.png

    Support

    PC7H

    2

    5 (7“)

    image-20250211-080024.png

    Support

    PC7D

    4

    16 (7“)

    Not support

    PC9D

    4

    16 (7“)

    Not support

    General Limit - System

     

    Max DS

    Max IM

    Total*

    Extra accessory

     

    Max DS

    Max IM

    Total*

    Extra accessory

    Basic 16 rooms

    8

    16

    20

    No need

    Extend 32 rooms

    8

    32

    40

    DH-SW4

    Extend 48 rooms

    8

    48

    56

    DH-SW4 + DH-LAN

    Extend 64 rooms

    8

    64

    72

    DH-SW4 + DH-LAN + DH-LAN

    *Total means all the 2Easy DH device in the system(include DH-LAN but not DH-RL1), for example basic 16 rooms situation, the system could has no more than 8 door stations, and no more than 16 montiors, but together shall not exceed 20 devices, such as /5 door stations with 15 monitors/, /4 door statons with 16 montiors/.

     

     