Menu
Default installer password “66666666”
For using door station DH622/DH611 only, the system type is DH-SS.
For using door station DH850/DH821 only, the system type is DH-APT.
Settings (DH-SS)
Menu information
Item | Value |
---|---|
System type | Setup the system type for the monitor, DH-SS or DH-APT |
Device_Addr | Monitor address, 2 digits |
MS_Nbr | Master/slave address setup |
Name | Monitor name |
Local_Nbr | Extension call numbers |
Manually setup monitor address in DH-SS
Tap the “Device_Addr” in the menu and input the 2 digital room numbers.
Tap the “MS_Nbr” in the menu and input MS_Nbr to set up master and slave settings.
01: Master
02~04: Slave
For DH-SS automatically setup address is supported in DH-SS onsite tool
Settings (DH-APT)
Menu information
Item | Value |
---|---|
System type | Setup the system type for the monitor, DH-SS or DH-APT |
RM_Addr | Monitor address, 2 digits |
MS_Nbr | Master/slave address setup |
Name | Monitor name |
Local_Nbr | Extension call number |
Global_Nbr | Extension call numbers. Reserved. |
Update Call_Nbr from RES | After configure RM_Addr, get Call_Nbr information form door station MAT according to configured RM_Addr (if has) |
Restore Call_Nbr default | Release the address setup, and set to default settings. |
Setup monitor address in DH-APT
Room address
Tap the “RM_Nbr” in the menu and input the 2 digital room numbers.
If the system has configured a MAT via the door station
After tapping “RM_Nbr” instead, the monitor will display the selectable MAT.
Tap “Input,” to manually input an address,
With MAT, it is not allowed to input addresses already programmed in the system.
For master and slave setup see below.
or select one from the MAT.
The MAT only shows the monitor address has not program yet, for the address already been programed will not show in the menu.
Master and Salve settings.
Tap the “MS_Nbr” in the menu and input the 2 digital room numbers.
If the system has configured a MAT via the door station
If MAT has been configured in the system, tap “MS_Nbr” will request to input the room number, and then select a Master/Slave address.
Room address input here will bypass the MAT unique device check.