Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

Version 1 Current »

Menu

image-20241105-030431.png

Default installer password “66666666”

For using door station DH622/DH611 only, the system type is DH-SS.

For using door station DH850/DH821 only, the system type is DH-APT.

Settings (DH-SS)

image-20241105-031224.png

Menu information

Item

Value

System type

Setup the system type for the monitor,

DH-SS or DH-APT
the value here will change the menu layout

Device_Addr

Monitor address, 2 digits

MS_Nbr

Master/slave address setup

Name

Monitor name

Local_Nbr

Extension call numbers

Manually setup monitor address in DH-SS

Tap the “Device_Addr” in the menu and input the 2 digital room numbers.

Tap the “MS_Nbr” in the menu and input MS_Nbr to set up master and slave settings.

01: Master

02~04: Slave

For DH-SS automatically setup address is supported in DH-SS onsite tool

Settings (DH-APT)

image-20241105-031332.png

Menu information

Item

Value

System type

Setup the system type for the monitor,

DH-SS or DH-APT
the value here will change the menu layout

RM_Addr

Monitor address, 2 digits

MS_Nbr

Master/slave address setup

Name

Monitor name

Local_Nbr

Extension call number

Global_Nbr

Extension call numbers. Reserved.

Update Call_Nbr from RES

After configure RM_Addr, get Call_Nbr information form door station MAT according to configured RM_Addr (if has)

Restore Call_Nbr default

Release the address setup, and set to default settings.

Setup monitor address in DH-APT

Room address

Tap the “RM_Nbr” in the menu and input the 2 digital room numbers.

If the system has configured a MAT via the door station

After tapping “RM_Nbr” instead, the monitor will display the selectable MAT.

image-20241105-034818.png

Tap “Input,” to manually input an address,

With MAT, it is not allowed to input addresses already programmed in the system.

For master and slave setup see below.

or select one from the MAT.

The MAT only shows the monitor address has not program yet, for the address already been programed will not show in the menu.

Master and Salve settings.

Tap the “MS_Nbr” in the menu and input the 2 digital room numbers.

If the system has configured a MAT via the door station

image-20241105-055720.png

If MAT has been configured in the system, tap “MS_Nbr” will request to input the room number, and then select a Master/Slave address.

Room address input here will bypass the MAT unique device check.

  • No labels