821-MK Keypad (for DH821VD)
Apperance and wiring
Use and steup
Call
Input room number and then press “#” to call.
Unlock
Input “#” first and following with 4 digital password to unlock the door.
Currently no code error beep tips.
Settings
Input “#” first and following with 4 digital admin code and end with “#”, after input the setting code togeter with setting value, “#” to confirm, if there is no setting value end with # directly
# + admin code + # setting code + setting value + #
For example bleow is a settings for setting up a new admin code, change password from default 1234 to new 4567.
# + 1234 + # 9104 + 4567 + #
Setting code
Currently no tips(beeps)/wrong tips(beeps) in settings.
Function | Setting code | Value | Details |
---|---|---|---|
Online update | 9101 | NA(end with # directly) | Online update with latest firmware. (via DH-LAN) |
Factory restore | 9102 | NA | Restore to factory default |
Reboot | 9103 | NA | reboot the unit |
Admin password | 9104 | 4 digits code | New admin password |
Public unlock 1 | 9301 | 4 digits code | public unlock code 1 for lock 1 |
Public unlock 1 | 9302 | 4 digits code | public unlock code 2 for lock 1 |
Private unlock | 9305 | 3 digits ID + 4 digits code | From ID 001 - 999 (999 codes) to storage private code. example, 001 and unlock code 3456 # admin code # 9305 001 3456 # To setup, set again for ID 001 will cover the old code. |
Lock 1 mode | 9306 | 2 digits code 00 or 01 | 00 means normally open 01 means normally close |
Lock 1 time | 9307 | 2 digits code 01-99 | 01 - 99 seconds for lock1 |