Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

To Factory Default

Restore IX device to factory default

Restore to factory default

Door station IX850

When door station IX850 in “Installer Mode”, tap “Installer Mode” -> “settings” -> “Restore and backup” ->tap once again to confirm

Item

Not Restore

Restore

description

Access Card

 

Restore to None

Installer settings

 

 

Password

 

All PWD

Manager settings

 

 

Voice promote files

 

 

Language translate

 

 

Virtual user

 

Delete All

DT-IM

 

Delete All

Call record

 

 

Customization RES

 

Logo/Icon files

R8001 (RES)

 

A RES base file

Monitor IX471S

Tap “Settings” -> “Manager” -> “Backup and restore” -> “Restore factory settings”, tap once again to confirm

 

Item

Not Restore

Restore

description

Installer settings

 

 

Password

 

Private password

User settings

 

Ring tune settings

Language translate

 

 

Call record

 

Delete all

Customization RES

 

Logo/Icon files

R8001 (RES)

 

A RES base file

 Different levels to restore IX471S
  1. Restore from Backup
    1.1 Tap “Restore installer bak1”,this IX471S will restore to the installer settings from latest file of backup

    1.2 On other IX471S (must in the same IP system), tap rightmost side of ”Restore from: …”,then input Device_Addr of preset IX471S,could get the Installer setting (excluding Call_Nbr and IP address) from backup file of preset IX471S

  2. Restore factory settings
    It will restore factory settings but keep the data of OEM.

  3. Restore default selective
    Able to make Single, Multiple or All selection, as below.

    3.1 Restore Installer default

    3.2 Resotore user default: Restore users settings to default (settings of Call tune,Call scene, General, etc.)

    3.3 Clear customizer: Delete all OEM data

    3.4 Clear Res: Delete all functions of List(eg. R8003 list, could written in IX471S by SD card. Use to set permission of cameras-monitoring. This list could be deleted by “Clear Res”)

    3.5 Clear user data: Delete Call record

    3.6 Clear backup: Delete backup file bak1

Outdoor station IX610

Bridge EB+ and EB-, and long press 15s to setup factory default       

Item

Not Restore

Restore

description

Installer settings

 

 

Voice promote files

 

 

Customization RES

 

Logo/Icon files

R8001 (RES)

 

A RES base file

Door Station IX821

Power on IX821, then short-circuit BOTH PORTS’ EB+ and EB- for 10 seconds at the same time (it is a little hard, please be patient and try more times), then IX821 will be set to factory default.

Video of operation as below:

IX821 restore to default.mp4

  • No labels