To Factory Default
Restore IX device to factory default
Restore to factory default
Door station IX850
When door station IX850 in “Installer Mode”, tap “Installer Mode” -> “settings” -> “Restore and backup” ->tap once again to confirm
Item | Not Restore | Restore | description |
Access Card | | • | Restore to None |
Installer settings | | • | |
Password | | • | All PWD |
Manager settings | | • | |
Voice promote files | • | | |
Language translate | • | | |
Virtual user | | • | Delete All |
DT-IM | | • | Delete All |
Call record | | • | |
Customization RES | • | | Logo/Icon files |
R8001 (RES) | • | | A RES base file |
Monitor IX471S
Tap “Settings” -> “Manager” -> “Backup and restore” -> “Restore factory settings”, tap once again to confirm
...
Expand |
---|
title | Different levels to restore IX471S |
---|
|
Restore from Backup 1.1 Tap “Restore installer bak1”,this IX471S will restore to the installer settings from latest file of backup 1.2 On other IX471S (must in the same IP system), tap rightmost side of ”Restore from: …”,then input Device_Addr of preset IX471S,could get the Installer setting (excluding Call_Nbr and IP address) from backup file of preset IX471S Restore factory settings It will restore factory settings but keep the data of OEM. Restore default selective Able to make Single, Multiple or All selection, as below. 3.1 Restore Installer default 3.2 Resotore user default: Restore users settings to default (settings of Call tune,Call scene, General, etc.) 3.3 Clear customizer: Delete all OEM data 3.4 Clear Res: Delete all functions of List(eg. R8003 list, could written in IX471S by SD card. Use to set permission of cameras-monitoring. This list could be deleted by “Clear Res”) 3.5 Clear user data: Delete Call record 3.6 Clear backup: Delete backup file bak1
Drawio |
---|
zoom | 1 |
---|
simple | 0 |
---|
inComment | 0 |
---|
pageId | 1181615383 |
---|
custContentId | 1191084090 |
---|
lbox | 1 |
---|
diagramDisplayName | 3restores |
---|
contentVer | 1 |
---|
revision | 1 |
---|
baseUrl | https://2easy-wiki.atlassian.net/wiki |
---|
diagramName | 3restores |
---|
pCenter | 0 |
---|
width | 1031 |
---|
links | |
---|
tbstyle | |
---|
height | 411 |
---|
|
|
Outdoor station IX610
Bridge EB+ and EB-, and long press 15s to setup factory default
...
Item | Not Restore | Restore | description |
Installer settings | | • | |
Voice promote files | • | | |
Customization RES | • | | Logo/Icon files |
R8001 (RES) | • | | A RES base file |
Door Station IX821
Power on IX821, then short-circuit BOTH PORTS’ EB+ and EB- for 10 seconds at the same time (it is a little hard, please be patient and try more times), then IX821 will be set to factory default.
...