Skip to end of metadata
Go to start of metadata

You are viewing an old version of this content. View the current version.

Compare with Current View Version History

Version 1 Next »

Typical wiring for apartments

1. with no more than 16 monitors

image-20241031-052419.png

Distance Limit

Cable Type

A

B

∑(A+B) Sum of Length

2 x 0.75 mm²

60 M

90 M

200 M

2 x 1.00 mm²

75 M

100 M

220 M

UTP cable (4 + 4 Combine)

40 M

40 M

140 M

2. with no more than 32 monitors

image-20241031-053638.png

Distance Limit

Cable Type

A

B

∑(A+B)

C

∑C

2 x 0.75 mm²

60 M

90 M

200 M

90 M

200 M

2 x 1.00 mm²

75 M

100 M

220 M

100 M

220 M

UTP cable

40 M

40 M

140 M

40 M

40 M

3. with no more than 48 monitors

image-20241031-060539.png

Distance Limit

Cable Type

A

B

∑(A+B)

C

∑C

D

∑D

Cat5

2 x 0.75 mm²

60 M

90 M

200 M

90 M

200 M

90 M

200 M

80 M

2 x 1.00 mm²

75 M

100 M

220 M

100 M

220 M

100 M

220 M

80 M

UTP cable

40 M

40 M

140 M

40 M

40 M

40 M

40 M

80 M

4. with no more than 64 monitors

image-20241031-061105.png

Distance Limit

Cable Type

A

B

∑(A+B)

C/D/E

∑C/D/E

Cat5

2 x 0.75 mm²

60 M

90 M

200 M

90 M

200 M

80 M

2 x 1.00 mm²

75 M

100 M

220 M

100 M

220 M

80 M

UTP cable

40 M

40 M

140 M

40 M

40 M

80 M

  • No labels