Typical wiring for apartments

1. with no more than 16 monitors

image-20241031-052419.png

Distance Limit

Cable Type

A

B

2 x 0.75 mm²

60 M

90 M

2 x 1.00 mm²

75 M

100 M

UTP cable (4 + 4 Combine)

40 M

40 M

2. with no more than 32 monitors

image-20241031-053638.png

Distance Limit

Cable Type

A

B

C

2 x 0.75 mm²

60 M

90 M

90 M

2 x 1.00 mm²

75 M

100 M

100 M

UTP cable

40 M

40 M

40 M

3. with no more than 48 monitors

image-20241031-060539.png

Distance Limit

Cable Type

A

B

C

D

Cat5

2 x 0.75 mm²

60 M

90 M

90 M

90 M

80 M

2 x 1.00 mm²

75 M

100 M

100 M

100 M

80 M

UTP cable

40 M

40 M

40 M

40 M

80 M

4. with no more than 64 monitors

image-20241031-061105.png

Distance Limit

Cable Type

A

B

C/D/E

Cat5

2 x 0.75 mm²

60 M

90 M

90 M

80 M

2 x 1.00 mm²

75 M

100 M

100 M

80 M

UTP cable

40 M

40 M

40 M

80 M