Support for externally powered lock
Number of locks supported : 1pcs
Lock time : 1 sec as default, 1~99 sec as optional
Lock mode: N/C & N/O, (N/O as default)
| DT616 Official version (PCB a1.2) |
---|---|
Power supply inside the lock | Support DC 12V no more than 500mA electric lock (with power supply PC7/PC7H only) |
Exit button | Not supported |
Support DC 12V no more than 500mA electric lock (with power supply PC7/PC7H only) | when less than 10A/250V AC lock, Or less than 10 A/30V DC DC lock, |
|
DT616 has no unlocking relay inside, a DS-ERL external relay accessory shall be used as a dry contact, and external power supply shall be used;