The wiring support for less than 16 monitors.
Wirings
Daisy Chain (In-out)
Star
Free runs
For free runs you can see the video:
https://youtu.be/kMTdMwHox3wStructure wiring
Use DH-BC4 instead of cable nuts/terminal block.
what is BC-4 and how it works:
https://2easy-wiki.atlassian.net/wiki/x/HAAGgQ
Distance limitation
General
Cable Type | A | B | ∑(A+B) The sum Length* |
---|---|---|---|
2 x 0.75 mm² | 60 M | 90 M | 200 M |
2 x 1.00 mm² | 75 M | 100 M | 220 M |
UTP cable (4 + 4 Combine) | 40 M | 40 M | 140 M |
More specific
In the case of using cable 2 x 0.75 mm²
From the power supply to door stations (A), it is less than 75 meters.
From the power supply to monitors less than 90 meters.
Summation of cables less than 200 meters.
Cable Type | 1 or 2 | 3 or 4 | 1+2+3+4 |
---|---|---|---|
2 x 0.75 mm² | 60 M | 90 M | 200 M |