A demo for how to setup a NS system
This manual will show how to install below project, a demo as below:
2 Buildings, each building as 2 room.
1 common door station.
Planning project
Plan network
Planning all network related issues.
PoE switch selection
In this demo, there are at least 7 network devices (include IP camera), by using 3 x 4 ports PoE switch, in case of future update (add more device or as replace)
Cabling
Wiring all cables, here we use Cat5 cable.
IP strategy selection and setup
Planning your IP strategy, here we use Auto-IP in this demo. Keep as default.
IP camera settings
No IP camera requires, if have follow:
According to IP strategy, we will need to configure all IP cameras as requires. To apply to Auto IP, set IP camera’s IP address in 192.168.240.0/20 subnet, as example, set the camera IP address: 192.168.243.199, mask: 255.255.240.0, sub-channel video code in H.264, Baseline, QVGA.
Plan Call_Nbr
Planning Call_Nbr, this relate to how you configure devices.
Call_Nbr selection
In this demo, the Call_Nbr in side building will using RM_Nbr.
For common building, to shorten input numbers use Global_Nbr.
Call_Nbr arrange
Each room setup as below:
Room | Device_Addr | Global_Nbr | |
Building 1 | Room 1 | NS00010001 | 101 |
Room 2 | NS00010002 | 102 | |
Building 2 | Room 1 | NS00020001 | 201 |
Room 2 | NS00020002 | 202 |
Configure Project
Power on all devices
Before configure device, we will need to installed and power on all device.
Configure IP settings
In this demo, we are using DHCP/AUTO, which is default settings, skip.
Configure Call_Nbr
Door station
Building 1 door station
In door station’s Call_Nbr setting menu, input “0001” for BD_Nbr
Building 2 door station
In door station’s Call_Nbr setting menu, input “0002” for BD_Nbr
Common door station
In door station’s Call_Nbr setting menu, input “0000” for BD_Nbr.
Monitor
Building 1 room 1 monitor
“Call_Nbr” set as “(NS)Network Complex” and input “00010001”, input “101” for Global_Nbr.
Building 1 room 2 monitor
“Call_Nbr” set as “(NS)Network Complex” and input “00010002”, input “102” for Global_Nbr.
Building 2 room 1 monitor
“Call_Nbr” set as “(NS)Network Complex” and input “00020001”, input “201” for Global_Nbr.
Building 2 room 2 monitor
“Call_Nbr” set as “(NS)Network Complex” and input “00020002”, input “202” for Global_Nbr.
Test with Project
Basic intercom function
Test with calling, monitoring, unlock doors.
Divert to APP
Test with APP to see if it works.
Maintain after installed
Add more device
Adding new monitor to room
set up “Call_Nbr” same as the monitor already exist in the room, and set different MS_Nbr.
Adding new outdoor station
Just run binding procedure once again, and binding a new outdoor station.
Adding new door station
Set DS_Nbr
Remove device
Simply uninstall device, noting needs to do with remove a device.
Replace device
In this demo, after replace device, settings as the first setup the devcies.