In SS scenario, IX610 works for only one room, bind with the master monitor in the room. Example: room 2 has one IX610, pair binding IX610 with master monitor RM_Nbr = 0002.

...

On door station IX821

By default, button form from bottom to top correspond RM_Nbr from 0001 ~ 0024

...

Press call button will call to monitors bind binding before

Call_Nbr setup for NS

In SS NS scenario, we need to setup BD_Nbr for door stations and monitors.

...

In “Call_Nbr” menu, set “Device_Addr “to “(NS) Network complex” and input 8digits integers, first 4 digits will be “BD_Nbr”, the last 4 will be “RM_Nbr”.  After, address display as “NS (BD_Nbr +RM_Nbr)” like below:

...

Example:  room  building 0002(RMBD_Nbr) in building room 0003(BDRM_Nbr), the Device_Addr input is 00020003

...

Example:  Door station in building 00030002(BD_Nbr), the BD_Nbr input shall is 0002. Common door station*, the BD_Nbr input shall is 0000

...

On common door station, input “00020003” (BD_Nbr +RM_Nbr) or “2103” (Global_Nbr) could call to this monitor.

While if slave monitor/s existexists, calling with RM_Nbr or BD_Nbr +RM_Nbr, slaves will also ring, calling with Local_Nbr or Global_Nbr, unless slaves has have same setupssetup, otherwise, they won’t ring.


 

Appendix 1

...

Chose your Call_Nbr

While planning a project, you should decide what Call_Nbr using in this system. Be aware, no matter which Call_Nbr using, Device_Addr setup is a must.

...