Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The wiring support for less than 16 monitors.

Wirings

Use DH-SW4 to extend the extra 16 monitors

...

Support wiring the same as Wiring 16 monitors (DH-SS/DH-APT)

  • Daisy Chain

  • Star

  • Free run

  • Structure wiring

Distance limitation

General

...

A: Power supply to door stations

B: Power supply to monitors, and to DH-SW4

C: DH-SW4 to monitors

Cable Type

A

B

∑(A+B) The sum Length*

C

2 x 0.75 mm²

60 M

90 M

200

90 M

2 x 1.00 mm²

75 M

100 M

220

100 M

UTP cable

(4 + 4 Combine)

40 M

40 M

140

40 M

More specific

image-20241202-031024.pngImage Added

Wiring 1 and Wiring 2 have the same rules,

In the case of using cable 2 x 0.75 mm²

  • From the power supply to door stations (A), it is less than 75 meters. ( Wiring 2 usually doesn’t has DS)

  • From the power supply to monitors less than 90 meters.

  • Summation of cables less than 200 meters.

...

Cable Type

...

1 or 2

...

3 or 4

...

1+2+3+4

...

2 x 0.75 mm²

...

60 M

...

90 M

...