Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

DT616 Official version (PCB a1.2)

Power supply inside the lock

Support DC 400mA 12V no more than 500mA electric lock (with power supply PC7/PC7H only)

Exit button

Not supported

when DC lock less than 400mA

Support DC 12V no more than 500mA electric lock (with power supply PC7/PC7H only)

when less than 10A/250V AC lock,

Or less than 10 A/30V DC DC lock,

Image RemovedImage Added

Note

DT616 has no unlocking relay inside, a DS-ERL external relay accessory shall be used as a dry contact, and external power supply shall be used;

...