2 Buildings, each building as 2 room.

1 common door station.

...

Planning project

Plan network

Planning all network related issues.

PoE switch selection

In this demo, there are at least 7 network devices (include IP camera), by using 3 x 4 ports PoE switch, in case of future update (add more device or as replace)

Cabling

Wiring all cables, here we use Cat5 cable.

IP strategy selection and setup

Planning your IP strategy, here we use Auto-IP in this demo.  Keep as default.

IP camera settings

No IP camera requires,  if have follow:

According to IP strategy, we will need to configure all IP cameras as requires. To apply to Auto IP, set IP camera’s IP address in 192.168.240.0/20 subnet, as example, set the camera IP address: 192.168.243.199, mask: 255.255.240.0, sub-channel video code in H.264, Baseline, QVGA.

Plan Call_Nbr

Planning Call_Nbr, this relate to how you configure devices.

Call_Nbr selection

In this demo, the Call_Nbr in side building will using RM_Nbr.

For common building, to shorten input numbers use Global_Nbr.

Call_Nbr arrange

Each room setup as below:

Room

Device_Addr

Global_Nbr

Building 1

Room 1

NS00010001

101

Room 2

NS00010002

102

Building 2

Room 1

NS00020001

201

Room 2

NS00020002

202

Configure Project

Power on all devices

Before configure device, we will need to installed and power on all device.

Configure IP settings

In this demo, we are using DHCP/AUTO, which is default settings, skip.

Configure Call_Nbr

Door station

Building 1 door station

In door station’s Call_Nbr setting menu, input “0001” for BD_Nbr

Building 2 door station

In door station’s Call_Nbr setting menu, input “0002” for BD_Nbr

Common door station

In door station’s Call_Nbr setting menu, input “0000” for BD_Nbr.

Monitor

Building 1 room 1 monitor

“Call_Nbr” set as “(NS)Network Complex” and input “00010001”, input “101” for Global_Nbr.

Building 1 room 2 monitor

“Call_Nbr” set as “(NS)Network Complex” and input “00010002”, input “102” for Global_Nbr.

Building 2 room 1 monitor

“Call_Nbr” set as “(NS)Network Complex” and input “00020001”, input “201” for Global_Nbr.

Building 2 room 2 monitor

“Call_Nbr” set as “(NS)Network Complex” and input “00020002”, input “202” for Global_Nbr.

Test with Project

Basic intercom function

Test with calling, monitoring, unlock doors.

Divert to APP

Test with APP to see if it works.

Maintain after installed

Add more device

Adding new monitor to room

set up “Call_Nbr” same as the monitor already exist in the room, and set different MS_Nbr.

Adding new outdoor station

Just run binding procedure once again, and binding a new outdoor station.

Adding new door station

Set DS_Nbr

Remove device

Simply uninstall device, noting needs to do with remove a device.

Replace device

In this demo, after replace device, settings as the first setup the devcies.