Call_Nbr, “Call Number”, a general name for multi parameters, which is used for calling, monitoring and addressing an IX device.
What is Call_Nbr
Call_Nbr is general name for calling relate numbers(strings), include below:
Device_Addr (Device Address, 10 digits, integer)
Device address is a combination of BD_Nbr (building number, 4 digits, integer), RM_Nbr (room number, 4 digits, integer) and MS_Nbr (master, slave number, 2 digits, integer)
...
Specially BD_Nbr = 0000, means public area of all buildings, RM_Nbr = 0000 usually for door station and guard units which means it assign to server all users but not particularly room.
Name
IX device’s name, which will be display in all other IX devices’ namelist or monitor list. This is a string type attribution.
In IX system, “Name” in namelist or monitor list is automatically synchronized.
Alias Number (Global_Nbr and Local_Nbr)
In most time you could call IX device with Device_Addr, RM_Nbr or Name, IX system offers extra alias number for calling. They are:
...
Local_Nbr is an alias number when using internally inside building, mainly using for device with same BD_Nbr calling. Same as Global_Nbr, could be integer or string.
IX device’s Call_Nbr
Below are IX devices’ Call_Nbr setting menu:
Monitor (IX471S/IX47/IX482)
Tap “Settings” -> “Installer” -> “Call_Nbr”,
Door Station IX850
When IX850 in installer mode, tap “Installer Mode” -> “Settings” -> “Call_Nbr”.
Outdoor station (IX610)
Door station IX610 could only bind with monitor, on the monitor (master):
...
Press and hold IX610 call button for 10s, each 5s, night view LED light up once. Release button with long beeps, monitor display “Binding OS succ” means it’s Call_Nbr has setup properly.
Door Station IX821
This door station could be only setup via onsite tool.
...
In onsite tool remote setup IX821, tap “Call_Nbr”
Scenarios in Call_Nbr
To simplify Call_Nbr setups, IX system Call_Nbr settings has 3 scenarios, each scenario with limit essential setups, scenarios are below:
...
· NS Network complex: housing complex, multi buildings or blocks, sharing some public gates, while each building or block has its own door station.
Call_Nbr setup for VS
In VS scenario, BD_Nbr and RM_Nbr are fixed parameters*, which is not need to pay attention. only take care of MS_Nbr.
*BD_Nbr fixed to 0099, and RM_Nbr fixed to 0001
Call_Nbr settings
Monitor IX471S/IX47/IX482
In “Call_Nbr” menu, set Device_Addr to “(VS) Single Family” if it is not:
...
MS_Nbr: if you have more than 1 monitor, rest monitor shall set up correct MS_Nbr. Such as 2nd monitor input 02.
Outdoor Station 610
By default, door station calling to address 0099 0001 without settings. Binding door station with the master monitor address in “(VS) Single Family”
Auto setup wizard
This setting is specially Call_Nbr setups in VS scenario, connected all device (new out of box), on any monitor (the one after wizard will be master)
...
this procedure will proceed all slave monitors and outdoor stations.
Call_Nbr setup for SS
In SS scenario, BD_Nbr is fixed parameters*, which is no need to pay attention.
*BD_Nbr = 0099 fixed in SS scenario
Call_Nbr settings
Monitor IX471S/IX47/IX482
In “Call_Nbr” menu, Set “Device_Addr “to “(SS) Standalone building” and input RM_Nbr. After, address display as “SS(RM_Nbr)” like below:
...
MS_Nbr: if you have more than 1 monitor, rest monitor shall set up correct MS_Nbr. Such as 2nd monitor input 02.
Door station IX850
By default, IX850 works for SS scenario.
...
DS_Nbr: this is MS_Nbr for door station IX850, if you have more than 1 door station IX850, rest door stations shall set up correct DS_Nbr. Such as 2nd door station input 02.
Outdoor station IX610
In SS scenario, IX610 works for only one room, bind with the master monitor in the room. Example: room 2 has one IX610, pair IX610 with master monitor RM_Nbr = 0002.
Door station IX821
By default, IX850 works for SS scenario, setup “BD_Nbr” to “0099” if it is not “0099”:
...
Same as door station IX850, setup DS_Nbr in “Call_Nbr” (By onsite tool) if have more than 1 door stations.
Make a call in VS
On door station IX850
Input RM_Nbr to call
Select name in namelist to call
On door station IX821
By default, button form bottom to top correspond RM_Nbr from 0001 ~ 0024
On outdoor station IX610
Press call button will call to monitors bind before
Call_Nbr setup for NS
In SS scenario, we need to setup BD_Nbr for door stations and monitors.
Call_Nbr settings
Monitor IX471S/IX47/IX482
In “Call_Nbr” menu, set “Device_Addr “to “(NS) Network complex” and input 8digits integers, first 4 digits will be “BD_Nbr”, the last 4 will be “RM_Nbr”. After, address display as “NS (BD_Nbr +RM_Nbr)” like below:
...
MS_Nbr: if you have more than 1 monitor, rest monitor shall set up correct MS_Nbr. Such as 2nd monitor input 02.
Door station IX850
By default, IX850 works for SS scenario.
...
*Common door station: door station in public area could call to all monitors.
Outdoor station IX610
Bind with the master monitor in the room.
Door station IX821
By default, IX850 works for SS scenario, setup “BD_Nbr”
...
IX821 doesn’t support work as common door station
Make a call in NS
On door station IX850
Input RM_Nbr to call
Select name in namelist to call
On common door station IX850
Input BD_Nbr and RM_Nbr to call, such as “00020003”
Select name in namelist to call
How Global_Nbr and Local_Nbr works
Global_Nbr and Local_Nbr are extra calling number, and they aren’t essential configures. Unlike device address, Global_Nbr and Local_Nbr could be duplicate in the system. Before configure these numbers, Device_Addr shall be setup correctly.
Setup Global_Nbr and Local_Nbr
On monitor IX471S/IX47/IX482, in “Call_Nbr”, fill in Global_Nbr and Local_Nbr
Call via Global_Nbr and Local_Nbr
On door station IX850 with same BD_Nbr (in same building), input Local_Nbr to call.
...
While if slave monitor/s exist, calling with RM_Nbr or BD_Nbr +RM_Nbr, slaves will also ring, calling with Local_Nbr or Global_Nbr, unless slaves has same setups, otherwise, they won’t ring.
Appendix 1
Choice your Call_Nbr
While planning a project, you should decide what Call_Nbr using in this system. Be aware, no matter which Call_Nbr using, Device_Addr setup is a must.
...
On door station, input “2” could call both monitors in room 2, while input “201”, to call reception, and input “202” to call logistics.
Appendix 2
Floor_Nbr (Floor number)
Floor_Nbr (Floor number) will only use when there is lift control module connected. The number is obtaining form RM_Nbr if floor number setting is none.
Refer “Lift Control” for more information.
Default Floor_Nbr: the first 2 digits of RM_Nbr is Floor_Nbr
Example: Device_Addr = (SS)0205, Floor_Nbr is 02; Device_Addr = (NS) 0001 0805, Floor_Nbr is 08.
Setup customize floor number
In “Settings” -> “Installer” -> “Parameter” -> “Others” -> 3rd page “Floor_Nbr”