This page shows the “Onsite Tool” to configure the 2Easy DH SS system. (DS1 shall be DH622)

Suitable for DH470/482.

onstietool~1.mp4

Before setup

The onsite tool menu will be different for “DH-SS” and “DH-APT”, this page shows the onsite tool menu for DH-SS.

Onsite tool for DH-APT:

What is system type:

Menu

2. DH SS onsite tool menu

Tap “Settings” → “Installer” → “Onsite Tool” to get into the tool menu.

image-20241030-032933.png

Management button

Refresh: scan all devices and refresh the dashboard

Multifamily: configure all monitor addresses from 1~8 automatically. (the address is randomly arranged)

Onefamily: configure all monitor addresses to 1, and configure master/slave automatically.

Clean: clean the address settings.

Test: run a communication test, from DS1 to check all monitors.

Line 1 data is the speed of the connection.

Line 2 data is the package lost rate.

Update all: batch update for all devices.

Reboot all: reboot all devices.

Without proper configuration, the “Update all” might not work, check with technical support for more information.

Remote configure

Tap the setting icons below the device to remote configure the device.

image-20241107-071433.png

The menu on the left tab:

Device

A read-only parameters, different types of devices offer different information, by at least:

Address, Name, Firmware version.

Call_Nbr

Configurable parameter for address.

Do not change the door station address via this menu, unless you know what this means.

Missing DS1 will lose connection to the system.

Parameter

Depending on the device, the parameters could be different.

Upgrade

Remote upgrade the monitor.

More

Depending on the device, the settings for more could be different. by at least has:

Reboot and restore factory settings.