Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Device address in IX system, 10 digits (must be unique)

Device_Addr Consist of 3 parts:

BD_Nbr

Building(Site&Block) number

4 digits

RM_Nbr

Room(Floor&Apartment) number

4 digits

MS_Nbr

Master/Slave number

2 digits

Device_Addr must be unique in one system

All numbers are digits only, and leading 0 must be kept

If 2 or more Monitors are installed in a room, and are assigned with same BD_Nbr+RM_Nbr. All Monitors will ring if a call is made, any one answering the call will cause others turn off automatically.

SYSTEM TYPE

DEVICE

BD_Nbr

RM_Nbr

MS/DS_Nbr

Device_Addr

VS

IM

0099(fixed)

0001(fixed)

01~32

00990001XX

VS

OS

0099(fixed)

0001(fixed)

01~32

00990001XX

SS

DS

0099(as default)

0000(fixed)

01~48

00990000XX

SS

IM

0099(as default)

0001~9999

01~32

0099XXXXXX

SS

OS

0099(as default)

0001~9999

51~82

0099XXXXXX

SS

BGL

0099(as default)

0000(fixed)

1~48

00990000XX

NS

CDS

0000(fixed)

0000(fixed)

1~48

00000000XX

NS

CGL

0000(fixed)

0000(fixed)

51~98

00000000XX

NS

DS

0001~1999

0000(fixed)

1~48

XXXX0000XX

NS

IM

0001~1999

0001~9999

01~32

XXXXXXXXXX

NS

OS

0001~1999

0001~9999

51~82

XXXXXXXXXX


MS_Nbr

MS_Nbr is for identification if multi device are installed in same location.

Allocation of MS_Nbr:

kept

00

--

for monitors IX471.IX439

01-32

01, Master as Default

for door station IX850.IX821

01-48

01, Master as Default

for door station IX610

51-82

51, Master as Default

For Master device, MS_Nbr can be ignored,show as: 0032 0101

For Slave device, MS_Nbr must be pointed out,show as: 0032 0101(02)


RM_ADDR, factory default

IX471,IX439

0099 0001 (01)

IX610

0099 0001 (51)

IX850

0099 0000 (01)


How to check and modify

Item Code

Check

Modify

IX471,IX439

“settings”→ “About” or (info) in main menu

“settings”→ “installer”→ “Call_Nbr”

IX850

“installer mode” →” settings”→”About”

“installer mode” →” settings”→”Call_Nbr”

IX610.IX821

via IX850 or IX471.IX439 in one system, “onsite tools” → search → ”Call_Nbr”

  • No labels