Preparation

Select the appropriate IP camera to access the system on demand. And set parameters for the IP camera.

Video Codec

An Onvif IP camera could be added to IP monitor IX471S, as long as this IPC could support following video codec: H264B、H264、H264H、H265、H265+

MJEPG decoding is not supported

Some IPC can support both audio and video streams, please select video stream

Preset the IP Camera before establishing a connection to the IX monitor

The setting interface of each IP camera brand are different.

Please set the following items according to the actual situation

Network

  • Choose to set DHCP or STATIC depending on the system

Video

Each stream type need to do setting separately

 

Main Stream

(Full screen)

Sub Stream

( Quad-view)

Tri-Stream

( App view)

Encoding

H264 or H265, MJPEG is not support

Resolution

1280*720

640*480

320*240

FPS( Frames per second)

acceptable setting range: 15 ~ 18, 15 is the Best recommendation

Bit Rate

700~1024kbs

512kbs~640kbs

512kbs~640kbs

BitRate Control

CBR is the Best recommendation

 

Add IP Camera to IX471S on site

1. Select the correct menu according to the actual situation

How to chose IPC or WLAN IPC when add camera to monitor

It depends on how the monitor is connected to the router where the IPC is located.

If it is wireless connected to PoE or Router which IPC attached , select WLAN IPC camera to add.

If it is wired connected to PoE or Router which IPC attached , select IPC camera

see below samples:

2. Add by search or manual

3. Login

input User name & PWD

4. Save

Delete IP camera

main menu → Settings → Ext.Unit → IPC camera / Wlan IPC camera → chose → Delete