Device_Addr Consist of 3 parts:

Image RemovedImage Added

BD_Nbr

Building(Site&Block) number

4 digits

RM_Nbr

Room(Floor&Apartment) number

4 digits

MS_Nbr

Master/Slave number or Device type

2 digits

Info

Device_Addr must be unique in one system

All numbers are digits only, and leading 0 must be kept

...

SYSTEM TYPE

DEVICE

BD_Nbr

RM_Nbr

MS/DS_Nbr

Device_Addr

VS

IM

0099(fixed)

0001(fixed)

01~32

00990001XX

VS

OS

0099(fixed)

0001(fixed)

51~82

00990001XX

SS

DS

0099(as default)

0000(fixed)

01~48

00990000XX

SS

IM

0099(as default)

0001~9999

01~32

0099XXXXXX

SS

OS

0099(as default)

0001~9999

51~82

0099XXXXXX

SS

BGL

0099(as default)

0000(fixed)

1~4851~82

00990000XX

NS

CDS

0000(fixed)

0000(fixed)

1~48

00000000XX

NS

CGL

0000(fixed)

0000(fixed)

51~98

00000000XX

NS

DS

0001~1999

0000(fixed)

1~48

XXXX0000XX

NS

IM

0001~1999

0001~9999

01~32

XXXXXXXXXX

NS

OS

0001~1999

0001~9999

51~82

XXXXXXXXXX

...