Configure and how to works with guard unit

What is guard unit

A guard unit is more like a monitor type door station, it could call all monitors and door stations, usually for concierge. Guard unit has below functions.

...

·         Long-time monitoring.

Guard Unit in SS scenario

·         In SS (Standalone) scenario

·         Using DCHP&Auto. (If not, setup IP address setting first, and follow the guide)

Call_Nbr setup

Default installer password: 66666666

...

For more than one guard unit please setup GL_Nbr correctly. (01~32)

Add IP Camera

On IX471(GL) tap “” -> “Ext.Unit” -> “IP Camera”, tap “Add” to add IP cameras.

Refer “IP Camera” for more information.

Calling to a guard unit

On door station IX850/IX821

By Input “00” (or “000”,”0000”) to call to first guard unit.

On IX850, you could also call on “namelist”, guard unit always on the top of the list.

On Monitor

Tap “intercom” -> “Guard Station” -> tap guard unit to call

Guard Unit in NS scenario

·         In NS (Network complex) scenario

·         Using DCHPDHCP&Auto. (If not, setup IP address setting first, and follow the guide)

...

Guard units serve for only the building, the guard unit is regular guard unit (GL)

...

Call_Nbr setup

On IX471(GL) in standby, tap “” -> “Installer” -> “Call_Nbr

If is a common guard unit, set BD BD_Nbr = 0000,

If it is working for particular building input the BD_Nbr.

Call_Nbr is general name for calling relate numbers(strings), include below:

Guard unit functions

Monitoring and unlock

First time running GL471, please check the monitoring list at least one time.

...

Also, by tap on “Monitor” icon the main menu, could monitoring IP cameras and DoorsDoor stations. In this page, the monitoring will automatically switch to next device very every 30s.

...

Call Monitor

Tap “functions” -> “Namelist

...