Device_Addr Consist of 3 parts:
BD_Nbr | Building(Site&Block) number | 4 digits |
RM_Nbr | Room(Floor&Apartment) number | 4 digits |
MS_Nbr | Master/Slave number or Device type | 2 digits |
Info |
---|
Device_Addr must be unique in one system All numbers are digits only, and leading 0 must be kept |
...
SYSTEM TYPE | DEVICE | BD_Nbr | RM_Nbr | MS/DS_Nbr | Device_Addr |
---|---|---|---|---|---|
VS | IM | 0099(fixed) | 0001(fixed) | 01~32 | 00990001XX |
VS | OS | 0099(fixed) | 0001(fixed) | 01~3251~82 | 00990001XX |
SS | DS | 0099(as default) | 0000(fixed) | 01~48 | 00990000XX |
SS | IM | 0099(as default) | 0001~9999 | 01~32 | 0099XXXXXX |
SS | OS | 0099(as default) | 0001~9999 | 51~82 | 0099XXXXXX |
SS | BGL | 0099(as default) | 0000(fixed) | 1~4851~82 | 00990000XX |
NS | CDS | 0000(fixed) | 0000(fixed) | 1~48 | 00000000XX |
NS | CGL | 0000(fixed) | 0000(fixed) | 51~98 | 00000000XX |
NS | DS | 0001~1999 | 0000(fixed) | 1~48 | XXXX0000XX |
NS | IM | 0001~1999 | 0001~9999 | 01~32 | XXXXXXXXXX |
NS | OS | 0001~1999 | 0001~9999 | 51~82 | XXXXXXXXXX |
...
Allocation of MS_Nbr:
kept | 00 | -- |
---|---|---|
for monitors IX471IX471S.IX439IX482 | 01-32 | 01, Master as Default |
for door station IX850.IX821 | 01-48 | 01, Master as Default |
for door station IX610 | 51-82 | 51, Master as Default |
Info |
---|
For Master device, MS_Nbr can be ignored,show as: 0032 0101 For Slave device, MS_Nbr must be pointed out,show as: 0032 0101(02) |
...
RM_ADDR, factory default
IX471IX471S,IX439IX482 | 0099 0001 (01) |
IX610 | 0099 0001 (51) |
IX850 | 0099 0000 (01) |
...
How to check and modify
Item Code | Check | Modify |
---|---|---|
IX471IX471S,IX439IX482 | “settings”→ “About” “Installer”→ “Call_Nbr” or in main menu | “settings”→ “installer”→ “Call_Nbr” |
IX850 | “installer mode” →” settings”→”About” | “installer mode” →” settings”→”Call_Nbr” |
IX610.IX821 | via IX850 or IX471.IX439 in one system, “onsite tools” → search → ”Call_Nbr” |
...