Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Device_Addr Consist of 3 parts:

Image RemovedImage Added

BD_Nbr

Building(Site&Block) number

4 digits

RM_Nbr

Room(Floor&Apartment) number

4 digits

MS_Nbr

Master/Slave number or Device type

2 digits

Info

Device_Addr must be unique in one system

All numbers are digits only, and leading 0 must be kept

...

SYSTEM TYPE

DEVICE

BD_Nbr

RM_Nbr

MS/DS_Nbr

Device_Addr

VS

IM

0099(fixed)

0001(fixed)

01~32

00990001XX

VS

OS

0099(fixed)

0001(fixed)

01~3251~82

00990001XX

SS

DS

0099(as default)

0000(fixed)

01~48

00990000XX

SS

IM

0099(as default)

0001~9999

01~32

0099XXXXXX

SS

OS

0099(as default)

0001~9999

51~82

0099XXXXXX

SS

BGL

0099(as default)

0000(fixed)

1~4851~82

00990000XX

NS

CDS

0000(fixed)

0000(fixed)

1~48

00000000XX

NS

CGL

0000(fixed)

0000(fixed)

51~98

00000000XX

NS

DS

0001~1999

0000(fixed)

1~48

XXXX0000XX

NS

IM

0001~1999

0001~9999

01~32

XXXXXXXXXX

NS

OS

0001~1999

0001~9999

51~82

XXXXXXXXXX

...

Allocation of MS_Nbr:

kept

00

--

for monitors IX471IX471S.IX439IX482

01-32

01, Master as Default

for door station IX850.IX821

01-48

01, Master as Default

for door station IX610

51-82

51, Master as Default

Info

For Master device, MS_Nbr can be ignored,show as: 0032 0101

For Slave device, MS_Nbr must be pointed out,show as: 0032 0101(02)

...

RM_ADDR, factory default

IX471IX471S,IX439IX482

0099 0001 (01)

IX610

0099 0001 (51)

IX850

0099 0000 (01)

...

How to check and modify

Item Code

Check

Modify

IX471IX471S,IX439IX482

“settings”→ “About” “Installer”→ “Call_Nbr” or (info) in main menu

“settings”→ “installer”→ “Call_Nbr”

IX850

“installer mode” →” settings”→”About”

“installer mode” →” settings”→”Call_Nbr”

IX610.IX821

via IX850 or IX471.IX439 in one system, “onsite tools” → search → ”Call_Nbr”

...