开锁时间设置

step1. 进入设置状态

DT616上电10s内,按住Call键直到听到3次”BP”音后松开(每秒会响“BP”一声),进入开锁时间设置状态,指示灯慢闪;[此状态维持10s,10s无操作后自动退出]

step2. 设置开锁时间

长按住Call键设置开锁时间,按住的时长=开锁时间,可设置01-99s时间,默认1s;

设置过程中会通过”BP”音提示时间,每响一声为1s;

Info

也可通过分机代码远程设置开锁时间;

step3. 保存&退出

  1. 设置后,无操作10s内自动保存并退出;

  2. 设置后,室外机断电自动保存并退出;

开锁模式设置

step1. 进入设置状态

DT616上电10s内,按住Call键直到听到6次”BP”音后松开(每秒会响“BP”一声),进入开锁模式设置状态,指示灯快闪;[此状态维持10s,10s无操作后自动退出]

step2. 设置开锁模式时间

按下Call键来回切换开锁模式;

设置过程中会通过”BP”音提示NC/NO模式,默认NO模式;

Info

也可通过分机代码远程设置开锁模式;

step3. 保存&退出

  1. 设置后,无操作10s内自动保存并退出;

  2. 设置后,室外机断电自动保存并退出;

...

设置操作

...

提示音

...

指示灯

...

说明

...

进入开锁时间设置状态

...

响3次BP音

...

慢闪

...

进入开锁模式设置状态

...

响6次BP音

...

快闪

...

开锁时间设置

...

BP音

...

慢闪

...

设置常开NO模式(默认)

...

BP+长音

...

快闪

...

开锁时输出+12V电压

...

设置常闭NC模式

...

BP,BP二声

...

快闪

...

设置后LK+、LK-端口一直输出+12V电压

...

退出设置

...

-

...

常亮

...

Table of Contents

...

Unlock Time Setup

Step1. Enter the setup state

Within 10 seconds after power-on, press and hold the Call key until the "BP" sound is heard for 3 times and then release it (the "BP" sound will be heard once per second) to enter the unlocking time setting state, and the indicator light will flash slowly;

Info

This state is maintained for 10 seconds, and automatically exits after 10 seconds of no operation.

Step2. Set the unlock time

Press and hold the Call key for a long time to set the unlocking time.

The time of pressing and holding is equal to the unlocking time.

The time of 01-99s can be set. The default is 1 s;

In the setting process, the time will be prompted by the "BP" sound, and each sound is 1 s;

Info

The unlocking time can also be set remotely through the monitor with code;

Step3. Save & Exit

After setting, automatically save and exit within 10s without operation;

or the outdoor unit will automatically save and exit when the power is off;

...

Unlock mode setup

Step1. Enter the setup state

Within 10 seconds after power-on, press and hold the Call key until the "BP" sound is heard for 6 times and then release it (the "BP" sound will be heard once per second) to enter the unlocking mode setting state, and the indicator light will flash quickly;

Info

This state is maintained for 10 seconds, and automatically exits after 10 seconds of no operation.

Step2. Set Unlock Mode Time

Press the Call key to switch the unlocking mode back and forth;

The NC/NO mode will be prompted by the "BP" sound during the setting process,

BP + long tone, representing NO,

two tones of BP, representing NC

The defaultand is NO mode

Info

The unlocking mode can also be set remotely through the extension code.

Step3. Save & Exit

After setting, automatically save and exit within 10s without operation;

or the outdoor unit will automatically save and exit when the power is off;

Setup

Prompt tone

Indicator light

Remark

Enter the unlocking time setting state

3 BPs

Slow flash

Enter the unlocking mode setting state

6 BPs

Quick flash

Unlock time setting

BPs

Slow flash

NO mode

BP + long tone

Quick flash

Output + 12 V when unlocked

NC mode

two tones of BP

Quick flash

After setting, the LK + and LK- ports always output + 12V voltage.

Exit

-

always on