Allocation of MS_Nbr:

kept

00

--

for monitors IX471IX471S.IX439IX482

01-32

01, Master as Default

for door station IX850.IX821

01-48

01, Master as Default

for door station IX610

51-82

51, Master as Default

Info

For Master device, MS_Nbr can be ignored,show as: 0032 0101

For Slave device, MS_Nbr must be pointed out,show as: 0032 0101(02)

...

RM_ADDR, factory default

IX471IX471S,IX439IX482

0099 0001 (01)

IX610

0099 0001 (51)

IX850

0099 0000 (01)

...

How to check and modify

Item Code

Check

Modify

IX471IX471S,IX439IX482

“settings”→ “About” “Installer”→ “Call_Nbr” or (info) in main menu

“settings”→ “installer”→ “Call_Nbr”

IX850

“installer mode” →” settings”→”About”

“installer mode” →” settings”→”Call_Nbr”

IX610.IX821

via IX850 or IX471.IX439 in one system, “onsite tools” → search → ”Call_Nbr”

...