Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

IX-RLC has 3 main functions:

...

...

Lock actuator.

...

Offline time server.

This article mainly for function 2 and 3.

Table of Contents
minLevel1
maxLevel7

...


Connectors and Indicators:

...

Micro USB and Update key: use for firmware update.

...

Lock1: lock1 terminal. As below

...

Lock connections


You could connect only lock1 or lock2 with inner 12V, the reset must be dry contact.

...

...

System Connections

Connected to same network with IX devices:

...


 

...

Setup to work with IX850

On the door station (IX850) needs to work with IX-RLC as lock actuator.

...

After setup the parameters, unlock the door station via monitor to apply changes (or restart the IX-RLC)!

...

DIP address setup of IX-RLC

To setup to works with IX-RLC, setup as below:

...

Lock 2 external address: 009999201011

 

...

Set IX-RLC as offline time server.

Because IX-RLC can “run” the time, and then “pass” to all items in the same IP system.

We could use IP monitor IX471/IX439, or use door station IX850, to configure IX-RLC remotely.

Way 1 (TD setup by IX monitor remotely)

Step 1, use IX471 to enter setup pages of IX-RLC

...

-> At last, tap “Time update” to “pass” the time/date to all items in the same IP system

Way 2 (TD setup by IX850 remotely)

Step 1, use IX850 to enter setup pages of IX-RLC

...

-> At last, tap “Time update” to “pass” the time/date to all items in the same IP system

 

...

Restore factory setting

Toggle back and forth DIP2 quickly (five times totally), and then power LED will flash (that means IX-RLC is restoring). At last power LED will be stable on (that means restore is finished)

...